Overview
The Most Trusted Solution for Group E Metals
- 150 CFM – 180 CFM options
- rated Class I, Div 1 – Group D and Class II, Div 1 – Groups E, F, and G environments
- continuous duty operation – run 24/7
- portable and compact with increased performance and technologies
- 10′ – 25’ of hose lengths
- up to 2″ hose diameter
- multi-user functionality (up to 2 operators for certain applications)
- safely collect and neutralize aluminum, titanium, magnesium, zirconium, mixed metals, sodium azides, TNT, high explosives and other volatile dusts
- the preferred solution for the Additive Manufacturing Industry
Vacuum Certifications and Classifications:
- Class I, Div 1 – Group D and Class II, Div 1 – Groups E, F, and G environments.
- ETL certification to UL and CSA Standards.
Utilizing a liquid-based filter system
Safely collect and neutralize:
- aluminum
- titanium
- magnesium
- zirconium
- mixed metals
- sodium azides
- TNT + high explosives
- other volatile dusts
NFPA 484 Requires Independent Grounding:
NFPA 484 Compliance Standards require that all wet mix immersion vacuum systems have an independent ground from the facilities electrical system. See Ruwac’s solution!
Industries and Applications:
• Additive manufacturing
• Automotive vehicle part manufacturers
• Air bag manufacturers
• Aviation part manufacturers
• Aluminum
• Magnesium
• Titanium
• Zirconium
• Conductive metals and Group E dusts
• Gun powder manufacturers
• Impact sensitive materials
• 3D Printing
• Laser Sintering
• Fine Metal Powders
Models Available:
Specifications
*Specs subject to change without notice
MX361EX MORE INFO
Motor Rating: | Power: | AMPS: | Hp: | CFM: | H20": | Filter Size: | Capacity: | Vacuum Weight: |
---|---|---|---|---|---|---|---|---|
Explosion Proof TEFC Motor / Class I, Div 1, 2, Group D, Class II Div 1, 2, Groups E, F & G | 120/1/60 | 16 AMPS | 1.5 Hp | 150 CFM | 75" H20 | 44 sq. ft. hydrophobic | 12 Gallons | 313 lbs. |
MX362EX
Motor Rating: | Power: | AMPS: | Hp: | CFM: | H20": | Filter Size: | Capacity: |
---|---|---|---|---|---|---|---|
Explosion Proof TEFC Motor / Class I, Div 1, 2, Group D, Class II Div 1, 2, Groups E, F & G | 240/1/60 | 8 AMPS | 1.5 Hp | 150 CFM | 75" H20 | 44 sq. ft. hydrophobic | 12 Gallons |
MX363EX
Motor Rating: | Power: | AMPS: | Hp: | CFM: | H20": | Filter Size: | Capacity: | Vacuum Weight: |
---|---|---|---|---|---|---|---|---|
Three Phase Explosion Proof TEFC Motor / Class I, Div 1, 2, Group D, Class II Div 1, 2, Groups E, F & G | 230/3/60 | 8 AMPS | 3 Hp | 180 CFM | 78" H20 | 44 sq. ft. hydrophobic | 12 Gallons | 400 lbs. |
MX364EX
Motor Rating: | Power: | AMPS: | Hp: | CFM: | H20": | Filter Size: | Capacity: | Vacuum Weight: |
---|---|---|---|---|---|---|---|---|
Three Phase Explosion Proof TEFC Motor / Class I, Div 1, 2, Group D, Class II Div 1, 2, Groups E, F & G | 460/3/60 | 4 AMPS | 3 Hp | 180 CFM | 78" H20 | 44 sq. ft. hydrophobic | 12 Gallons | 338 lbs. |
MX365EX MORE INFO
Motor Rating: | Power: | CFM: | H20": | Filter Size: | Capacity: | Vacuum Weight: |
---|---|---|---|---|---|---|
Stainless Steel Air Venturi | Air Powered | 150 CFM | 135" H20 | 44 sq. ft. hydrophobic | 12 Gallons | 248 lbs. |
Features and Benefits
MX360EX Series
For Group E Metal Dust
Used in Class I, Division 1, 2 – Group D; Class II, Division 1, 2 – Group E Atmospheres
– ETL Certified to UL 1203 and CSA 22.2 – CERTIFIED EXPLOSION PROOF
– 12 Gallon Immersion Tank
– Independently Bonded and Grounded to Minimize Static Discharge
– Explosion Proof TEFC Motor for Continuous Duty Operation
– Vacuum Engineered for Supreme Durability and Ease of Maintenance
– Single Phase or Three Phase Options (120/1/60, 240/1/60, 230/3/60, or 460/3/60)
*Air Powered Vacuum System Available.
Technology and Benefits:
With 100% of intake air being completely submerged and neutralized in the immersion separation “liquid bath”, the chance of an outside ignition source entering the wet mixer vacuum is safely ruled out. Utilizing a liquid-based filter system, the MX360EX Series vacuum will safely collect and neutralize aluminum, titanium, magnesium, zirconium, mixed metals, sodium azides, TNT, high explosives and other volatile dusts.